Drive

For Mini Linear Units MGBS & MGTB and MCE & MSCE Mini Electric Cylinders & Sliders.

See documentation below for more information.

Dimensions in mm.
Download PDF code.product.loadingpdf
+ Tilføj til PDF-katalog

Product Information

Designation Select all Lead Time * Compatible with Operating Voltage (V DC) Protocol/Control Ambient Temperature (°C) Ambient Humidity Duty Cycle Current Consumption (mA) Rotational Speed (rpm) Supported Resolution (ppr) Input Signals Output Signals Vibration Resistance (G) Motor Current (A) CAD Compare
/storage/91E0F886398BE457260EDBD1ACB3E5A45A113A0F9554D566FF40FC9AEDF6458C/c50bf7c097864722a25139dbd9753da3/STP/media/6d92cfffbaa74da49c10310a5267209a/CAD_STDF-28-A-EC_Drive_Rollco.STP 2 STMN-28-L-… 24 ± 10 % EtherCAT 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 3 dedicated inputs (LIMIT+, LIMIT–, ORIGIN) ; 7 user inputs (Photocoupler) 6 user outputs (Photocoupler) ; Brake 0.5 -
Get quote
/storage/15C03C652BBE9DA86B1F778EDEC0CD49E9D1974A3778EE6199E521FCE58BDC45/25d3fa85b489426597c28f4f177e6efa/STP/media/ac02c039022b4152a2fa163aa2e8d3ea/CAD_STDF-28-A-EN_Drive_Rollco.STP 2 STMN-28-L-… 24 ± 10 % Ethernet based communication 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 3 dedicated inputs (LIMIT+, LIMIT–, ORIGIN) ; 9 Programmable inputs (Photocoupler) 1 dedicated output (Compare out) ; 9 programmable outputs (Photocoupler) ; Brake 0.5 -
Get quote
/storage/C3028377181AF48CFD613EB0D68A1BEEFEFC1E516DBCCB1131F5B2F93B4E309B/06e3fa09166a420abfddf4c3db2bcb1d/STP/media/f0224593e2044c7a933eb867f5ecd6b1/CAD_STDF-28-A-PD_Drive_Rollco.STP 2 STMN-28-L-… 24 ± 10 % Pulse/direction control 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 Position command pulse ; Servo on/off ; Alarm reset (Photocoupler input) In-position ; Alarm (Photocoupler output) ; Encoder signal, brake 0.5 -
Get quote
/storage/3E8C47FC7041D584025710523BB2C62D35DFC189EE2E7D893BF223D4835998DC/a559a7e131c94b55b9276a2bb7782d81/STP/media/5d1478e0ba6a4d6c8d2bcb16ef7ff397/CAD_STDF-42-A-EC_Drive_Rollco.STP 2 STMN-42-L-… 24 ± 10 % EtherCAT 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 3 dedicated inputs (LIMIT+, LIMIT–, ORIGIN) ; 7 user inputs (Photocoupler) 6 user outputs (Photocoupler) ; Brake 0.5 -
Get quote
/storage/82EB4275795552BCA7DBAF15FFD7252C8059D79CCD319C49E9975D57B0D41C60/f3b0c81a900e454ba4af255f663b9bee/STP/media/92f0edb1e554454cb2ccdef8ea0e17d7/CAD_STDF-42-A-EN_Drive_Rollco.STP 2 STMN-42-L-… 24 ± 10 % Ethernet based communication 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 3 dedicated inputs (LIMIT+, LIMIT–, ORIGIN) ; 9 Programmable inputs (Photocoupler) 1 dedicated output (Compare out) ; 9 programmable outputs (Photocoupler) ; Brake 0.5 -
Get quote
/storage/0928266E3C3CCD5B51D80C5405B1B39D828884FB5F90D1B9DB03AF9058721F90/016fd853b9314791bd2ffcc22be42bac/STP/media/ede22cadf8b04cbebee7c149fe73563a/CAD_STDF-42-A-PD_Drive_Rollco.STP 2 STMN-42-L-… 24 ± 10 % Pulse/direction control 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 Position command pulse ; Servo on/off ; Alarm reset (Photocoupler input) In-position ; Alarm (Photocoupler output) ; Encoder signal, brake 0.5 -
Get quote
/storage/9CCE139CFBABF75D2272B8F7AE8C827C9B03B6CA4A5D81C6C315348292BB22CF/6a798a3bf51446ea9b970300495fc658/STP/media/7b8df5d5c07c47e2a92332015bf86166/CAD_STDF-56-A-EC_Drive_Rollco.STP 2 STMN-56-L-… 24 ± 10 % EtherCAT 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 3 dedicated inputs (LIMIT+, LIMIT–, ORIGIN) ; 7 user inputs (Photocoupler) 6 user outputs (Photocoupler) ; Brake 0.5 -
Get quote
/storage/7D063F7009A6BEBF9E3A561E0BC30BA3A2E773BB03BC4FDD396F3492607F86B0/847ca6fc55874627b2851c14c5a64182/STP/media/1bac4e03da1e41609be58e4c60c7483e/CAD_STDF-56-A-EN_Drive_Rollco.STP 2 STMN-56-L-… 24 ± 10 % Ethernet based communication 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 3 dedicated inputs (LIMIT+, LIMIT–, ORIGIN) ; 9 Programmable inputs (Photocoupler) 1 dedicated output (Compare out) ; 9 programmable outputs (Photocoupler) ; Brake 0.5 -
Get quote
/storage/2B8BC4D2F2DED5EB68F0FCB2DAFBD614F2099B0DE3DECFD1B5891FBEE5A62D25/45f1c9c862ff486391ad35ab60094363/STP/media/893e3a43520a48aabcbdb5099a867e3a/CAD_STDF-56-A-PD_Drive_Rollco.STP 2 STMN-56-L-… 24 ± 10 % Pulse/direction control 0 ~ +50 35 ~ 80 % 100 % Max. 500 0 ~ 3000 500, 1000, 1600, 2000, 3600, 5000, 6400, 7200, 10000 Position command pulse ; Servo on/off ; Alarm reset (Photocoupler input) In-position ; Alarm (Photocoupler output) ; Encoder signal, brake 0.5 -
Get quote
/storage/BAF099EFF53494BA18A0B01E8DD2BF785CBE1583602A03A26BB268D819238412/33e0b4ea2c1f4826bb95e8c2c0866539/stp/media/f8de51331290417cbc46c3585e837f53/CAD_STDL-040-C-PN_Drive_Rollco.stp 2 STMN-... 20–50 Profinet 0–40 10–90 % - Max. 160 Depending on stepper motor - 8 Digital inputs : 1 Analog input ; 1 Encoder input A, B, I 3 Digital outputs <1 1.0–4.5
Get quote

*Green: Normally in stock, contact us for current status. Blue: Contact us for delivery time.